50 Tr Cooling Tower
50 Tr Cooling Tower

50 Tr Cooling Tower

MOQ : 1 Unit

50 Tr Cooling Tower Specification

  • Motor
  • 3 Phase, 2 HP Electric Motor
  • Refrigerating Capacity
  • 50 TR (Tons of Refrigeration)
  • Air Flow
  • 5000-7000 CFM (cubic feet per minute)
  • Material
  • FRP (Fiber Reinforced Plastic) body
  • Application
  • Industrial cooling, HVAC, Chiller Systems, Process Cooling
  • Condition
  • New
  • Type
  • Induced Draft, Counter Flow Cooling Tower
  • Dimension (L*W*H)
  • 1500 x 1500 x 2100 mm (approximate)
  • Power Supply
  • Three Phase AC
  • Voltage
  • 415 V (Standard Industrial Voltage)
  • Cooling Type
  • Water Cooled
  • Nozzle Material
  • ABS / PVC
  • Cooling Coil Material
  • PVC / HDPE Fill Media
  • Water Flowing Rate
  • 225 LPM (Liters per Minute)
  • Water Pump Motor
  • 1.5 HP-2 HP (Suggested for circulation)
  • Noise Control
  • Low Noise Fan with Sound Attenuators
  • Compressor
  • Not Applicable (Cooling Tower)
  • Basin Capacity
  • 350 Liters
  • Max Inlet Water Temperature
  • Up to 45C
  • Structure
  • Hot Dipped Galvanized Steel or SS Support Frame
  • Fan Type
  • Axial Flow Fan with Aluminum Blades
  • Corrosion Resistance
  • High Corrosion Resistance due to FRP and Galvanized Steel
  • Maintenance
  • Easy Access Panel for Cleaning
  • Ambient Temperature
  • Designed for up to 50C
  • Water Distribution System
  • Rotary Sprinkler Head
  • Color
  • Blue (custom colors available on demand)
  • Drift Eliminator
  • PVC / FRP Moulded
  • Fill Type
  • Honeycomb PVC Fill Media
  • Service Life
  • 12-15 Years (With Proper Maintenance)
  • Weight
  • Approx. 350-420 kg (dry)
  • Operating Temperature Range
  • 5C to 45C
  • Installation Location
  • Outdoor / Terrace Mountable
  • Heat Exchange Area
  • 25-30 sq. m
 

50 Tr Cooling Tower Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 10-15 Days
 

About 50 Tr Cooling Tower



Discover an affordable yet scarce 50 Tr Cooling Tower engineered for maximum performance. Featuring an axial flow fan with aluminum blades and a noteworthy honeycomb PVC fill media, it ensures reduced drift and heightened cooling. The breathtaking heat exchange area of 25-30 sq. m, complemented by a robust FRP body and galvanized steel structure, offers unprecedented corrosion resistance. With a service life of 12-15 years and easy maintenance, this cooling tower provides reliability for industrial, HVAC, and process cooling needs. Limited supply-an opportunity not to be missed!

Primary Applications and Usage Directions

The 50 Tr Cooling Tower is predominantly used in industrial cooling, HVAC systems, and large-scale process cooling applications. Its design is suited for outdoor or terrace installations, ensuring adaptability across various environments. Direction of use: Connect to water-cooled systems via the rotary sprinkler head for optimal distribution. It is ideal for manufacturing units, commercial buildings, and chiller systems, providing reliable operation in areas with ambient temperatures up to 50C.


Domestic Market Reach and Exchange Valuation

Primarily serving the Indian domestic market, this cooling tower is supplied directly by leading exporters, manufacturers, and service providers. The outlay for delivery is efficiently managed, with typical turnaround times ranging from 2 to 4 weeks, reflecting its reduced availability and high valuation. Supply ability remains steady to match the growing demand for exchange in industrial and commercial cooling sectors, ensuring timely installation and consistent performance for enterprise clients.


FAQ's of 50 Tr Cooling Tower:


Q: How does the 50 Tr Cooling Tower ensure efficient heat exchange?

A: The tower utilizes a honeycomb PVC fill media and a robust axial flow fan, providing a broad heat exchange area of 25-30 sq. m, which results in efficient cooling and lower drift losses.

Q: What types of environments is this cooling tower best suited for?

A: It is ideal for outdoor or terrace-mounted setups in industrial, HVAC, or process cooling operations, thriving in ambient temperatures up to 50C due to high corrosion resistance and durable construction.

Q: When should I schedule maintenance for optimal performance?

A: Regular maintenance is recommended every 3-6 months. The easy access cleaning panel facilitates fast, straightforward cleaning and helps prolong the tower's impressive service life of 12-15 years.

Q: Where is the 50 Tr Cooling Tower primarily supplied?

A: This cooling tower is predominantly supplied across India through reputable exporters, manufacturers, and service providers with prompt delivery and support.

Q: What are the main benefits of the rotary sprinkler head water distribution?

A: The rotary sprinkler head ensures even water distribution, maximizing cooling efficiency and reducing hotspots within the system for consistent, dependable performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cooling Tower Category

500 TR FRP Cooling Tower

500 TR FRP Cooling Tower

Price 675000 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Natural Draft Cooling Towers

Application : Automobile Industry

Material : Other , Fiberglass Reinforced Polyester

Refrigerating Capacity : 500 TR

125 Tr Frp Cooling Tower

125 Tr Frp Cooling Tower

Minimum Order Quantity : 1 Unit

Type : Induced Draft Cooling Tower

Application : HVAC, Industrial Cooling, Process Cooling, Refrigeration Plants

Material : Other , FRP (Fiber Reinforced Plastic)

Refrigerating Capacity : 125 TR (Tons of Refrigeration)

80 Tr Cooling Tower

80 Tr Cooling Tower

Minimum Order Quantity : 1 Unit

Type : Induced Draft, Circular/ Bottle Type Cooling Tower

Application : Industrial Process Cooling, HVAC, Power Plants, Chemical Industries

Material : Other , FRP (Fiberglass Reinforced Plastic)

Refrigerating Capacity : 80 TR (Tons of Refrigeration)

30 Tr Cooling Tower

30 Tr Cooling Tower

Minimum Order Quantity : 1 Unit

Type : Induced Draft, Counterflow

Application : Industrial cooling, HVAC systems, Power Plants, Air Conditioning

Material : Other , FRP (Fibre Reinforced Plastic)

Refrigerating Capacity : 30 TR (Tons of Refrigeration)



Back to top